SciCon 1 Inch Single-Use Conductivity SensorThe SciCon combines temperature sensing capabilities with conductivity sensing capabilities in a compact, disposable, single-use package at a low price point. Each sensor is pre-programmed and barcoded with a unique ID for easy traceability and data documentation when combined with the SciLog SciDoc software. Factory calibration data is also stored on each sensor's chip for out-of-box, plug and play use. The SciCon comes in 5 different  sizes to fit a variety of tubing sizes: Luer, 3/8" barb, 1/2" barb, 3/4" TC (Tri-Clover), and 1.0" TC (Tri-Clover).

SciCon Features
  • Pre-Calibrated
  • NIST-Traceable
  • Certified Calibration
  • Gamma-Stable
  • Autoclavable & NaOH stable
  • Performance Tested
  • Scalable, Five Sizes
  • Real-Time Documentation

SciCon Conductivity Monitor

SciCon 1 Inch Single-Use Conductivity Sensor Monitor
The Sensor Monitor provides auto range conductivity from 1 μS/cm to 200 mS/cm, with an operating temperature range of 0 - 50° C and a temperature resolution of 0.1° C. When connected to a PC using the SciLog SciDoc software, documentation of the sensor data can be completely automated.

SciCon Product Information

SciCon Part Numbers & Specs

SciCon Sensors

Fluid Connector Part Number* Compatible Tubing Sizes Max Flow Rate Max PSI
Luer 080-599PSX-5
ID 0.03" to 0.31" 1 liters/min 60 psi
3/8" Barb 080-594PSX-5 ID 0.31" to 0.38" 8 liters/min 60 psi
1/2" Barb 080-595PSX-5 ID 0.50" 17 liters/min 60 psi
3/4" Tri-Clover (TC) 080-596PSX-5 Tubing with 3/4" TC 31 liters/min 60 psi
1.0" TC "Ladish" 080-597PSX-5 Tubing with 1" TC Ladish 60 liters/min 60 psi
*Part Numbers are for sensor 5 packs

SciCon Monitors

Voltage Part Number Form Factor
110 VAC 080-590 Bench-Top Monitor
220 VAC 081-590 Bench-Top Monitor
24 VDC 080-591 DIN Rail Mount
SciCon Sensing Element Specs
  • All wetted materials are made of animal-free compounds.
  • Material, Fluid Contact: Natural PP, Gold, The Natural PP meets USP Class VI and FDA 21 CFR 177.1520
  • Sensor Type: 4-electrode conductivity cell, Factory calibrated, Ready to use
  • Conductivity Range: 1 μS/cm to 200 mS/cm
  • Resolution: 0.1μS/cm
    • Accuracy: High Range: ± 0.25 mS in the 10-200 mS Range
    • Accuracy: Low Range: ± 3 μS in the 0-100 μS Range
    • Accuracy: ±2.5 mS of Full Range
  • Temperature Range: 4 - 50° Celsius
  • Temperature Probe: Thermistor, Factory Calibrated
  • Temperature Accuracy: ± 0.5° Celsius
  • Sensor Microchip: EPROM, stores Device ID, Cell Constant, Temp Offset & Factory Cal Data
SciCon Monitor Specs
  • Operating Mode: Auto range conductivity from 200 mS/cm to 1 μS/cm; Temperature: 0 - 50° C, resolution 0.1° C.
  • Sensitivity Range: 1 μS/cm to 200 mS/cm; Resolution: 0.1 μS/cm.
  • Accuracy: High Range: ± 0.25 mS in the 10 - 200 mS range; Low Range: ± 3 μS in the 0 - 100 μS range.
  • Analog Output: 4 to 20 mA, 18 Bit Resolution.
  • Digital Outputs: RS-232 and RS-485 for networking.
  • Alarm Outputs: 4 TTL, Hi/Lo Conductivity, Hi/Lo Temperature.
  • Power Supply: Wall Transformer (Lab Option); 115/230 VAC (Process Option).
  • Display: 2 Lines, 20 characters each, backlit.
  • Data Entry: 6 keys.

SOFTWARE - SELECTABLE PARAMETERS

  • Conductivity Unit: μS, mS, PPM of KCl, PPM of NaCl, 442.
  • User Selectable 4-20mA Span: 0% = 0 and 100% = 200 mS or any other Lo/Hi pair of conductance values. e.g. 5,000 μS to 80,000 μS.
  • Substantial Signal Offset Capability
  • Automatic Temperature Compensation
  • Edit Mode: Ability to adjust
    1. Reference Temperature
    2. Conductivity Value for a given Std Solution
    3. Serial Com Baud Rate
    4. Alarms
  • Time/Date: All Data Printout with Time/Date Stamp.
  • Lock-Out: On/Off, Requires Password (optional).
  • Re-Cal: Custom Calibration of Sensors.
Material Certificates
Performance Data
Regulatory Compliance