The SciCon combines temperature sensing capabilities with conductivity sensing capabilities in a compact, disposable, single-use package at a low price point. Each sensor is pre-programmed and barcoded with a unique ID for easy traceability and data documentation when combined with the SciLog SciDoc software. Factory calibration data is also stored on each sensor's chip for out-of-box, plug and play use. The SciCon comes in 5 different sizes to fit a variety of tubing sizes: Luer, 3/8" barb, 1/2" barb, 3/4" TC (Tri-Clover), and 1.0" TC (Tri-Clover).
SciCon Conductivity Monitor
![]()
The Sensor Monitor provides auto range conductivity from 1 μS/cm to 200 mS/cm, with an operating temperature range of 0 - 50° C and a temperature resolution of 0.1° C. When connected to a PC using the SciLog SciDoc software, documentation of the sensor data can be completely automated.
![]()
SciCon Product Information
- SciCon Part Numbers & Specs
-
SciCon Sensors
Connector Part Number Compatible Tubing Sizes Max Flow Rate Max PSI Luer 080-599PSX-5 ID 0.03" to 0.31" 1 liters/min 60 psi 3/8" Barb 080-594PSX-5 ID 0.31" to 0.38" 8 liters/min 60 psi 1/2" Barb 080-595PSX-5 ID 0.50" 17 liters/min 60 psi 3/4" Tri-Clover (TC) 080-596PSX-5 Tubing with 3/4" TC 31 liters/min 60 psi 1.0" TC "Ladish" 080-597PSX-5 Tubing with 1" TC Ladish 60 liters/min 60 psi SciCon Monitors
Voltage Part Number Form Factor 110 VAC 080-590 Bench-Top Monitor 220 VAC 081-590 Bench-Top Monitor 24 VDC 080-591 DIN Rail Mount - SciCon Sensing Element Specs
-
- All wetted materials are made of animal-free compounds.
- Material, Fluid Contact: Natural PP, Gold, The Natural PP meets USP Class VI and FDA 21 CFR 177.1520
- Sensor Type: 4-electrode conductivity cell, Factory calibrated, Ready to use
- Conductivity Range: 1 μS/cm to 200 mS/cm
- Resolution: 0.1μS/cm
- Accuracy: High Range: ± 0.25 mS in the 10-200 mS Range
- Accuracy: Low Range: ± 3 μS in the 0-100 μS Range
- Accuracy: ±2.5 mS of Full Range
- Temperature Range: 4 - 50° Celsius
- Temperature Probe: Thermistor, Factory Calibrated
- Temperature Accuracy: ± 0.5° Celsius
- Sensor Microchip: EPROM, stores Device ID, Cell Constant, Temp Offset & Factory Cal Data
- SciCon Monitor Specs
-
- Operating Mode: Auto range conductivity from 200 mS/cm to 1 μS/cm; Temperature: 0 - 50° C, resolution 0.1° C.
- Sensitivity Range: 1 μS/cm to 200 mS/cm; Resolution: 0.1 μS/cm.
- Accuracy: High Range: ± 0.25 mS in the 10 - 200 mS range; Low Range: ± 3 μS in the 0 - 100 μS range.
- Analog Output: 4 to 20 mA, 18 Bit Resolution.
- Digital Outputs: RS-232 and RS-485 for networking.
- Alarm Outputs: 4 TTL, Hi/Lo Conductivity, Hi/Lo Temperature.
- Power Supply: Wall Transformer (Lab Option); 115/230 VAC (Process Option).
- Display: 2 Lines, 20 characters each, backlit.
- Data Entry: 6 keys.
SOFTWARE - SELECTABLE PARAMETERS
- Conductivity Unit: μS, mS, PPM of KCl, PPM of NaCl, 442.
- User Selectable 4-20mA Span: 0% = 0 and 100% = 200 mS or any other Lo/Hi pair of conductance values. e.g. 5,000 μS to 80,000 μS.
- Substantial Signal Offset Capability
- Automatic Temperature Compensation
- Edit Mode: Ability to adjust
- Reference Temperature
- Conductivity Value for a given Std Solution
- Serial Com Baud Rate
- Alarms
- Time/Date: All Data Printout with Time/Date Stamp.
- Lock-Out: On/Off, Requires Password (optional).
- Re-Cal: Custom Calibration of Sensors.
- Material Certificates
-
- BSE Material Compliance Statement SciLog Disposable Sensors Rev A AD080610
- Material Compliance Statement Concerning Use of Latex SciLog Disposable Sensors.pdf Rev G SciLog Certificate of Compliance KS080210.pdf
- USP Biological Reactivity Tests In Vivo Material Compliance Statement SciLog Disposable Sensors.pdf
- USP Class VI Material Compliance Statement SciLog Disposable Sensors Rev A AD080610.pdf
- Performance Data
-
- Out-of-Box Sensor Performance SciCon Luer.pdf
- SciCon 100 Hour Exposure to 1.0 M NaOH.pdf
- SciCon 100 Hour Exposure to 70 percent IPA.pdf
- SciCon Low Conductivity Accuracy Data.pdf
- SciCon Post-Gamma Accuracy KS052610.pdf
- SciCon Post Autoclaving Sensor Response.pdf
- SciCon Sanitization 1.0N NaOH 20 C and 50 C.pdf
- SciCon Sensor Sanitization Summary.pdf
- Regulatory Compliance