The SciLog SciTemp provides high precision temperature sensing capabilities in a compact, disposable package at a low price point. Each sensor is pre-programmed and barcoded with a unique ID for easy traceability and data documentation when combined with the SciLog SciDoc software. Factory calibration data is also stored on each sensor's chip for out-of-box, plug and play use. The SciTemp comes in 5 different sizes to fit a variety of tubing sizes: Luer, 3/8" barb, 1/2" barb, 3/4" TC (Tri-Clover), and 1.0" TC (Tri-Clover).
SciTemp Temperature Monitors
The SciTemp Sensor Monitor provides an accuracy of +/- 0.10 °C in the 4.00 to 70.00 °C range, with an operating temperature range of -40 to +150 °C and a temperature resolution of 0.01 °C. When connected to a PC using the SciLog SciDoc software, documentation of the sensor data can be completely automated.
SciTemp monitors 2 temperature sensors and displays T1,T2 and Differential Temperature (DT).
![]()
SciTemp Product Information
- SciTemp Part Numbers & Specs
-
SciTemp Sensors
Connector Part Number Compatible Tubing Sizes Max Flow Rate Max PSI Luer 080-799PSX-5 ID 0.03" to 0.31" 1 liters/min 60 psi 3/8" Barb 080-794PSX-5 ID 0.31" to 0.38" 8 liters/min 60 psi 1/2" Barb 080-795PSX-5 ID 0.50" 17 liters/min 60 psi 3/4" Tri-Clover (TC) 080-796PSX-5 Tubing with 3/4" TC 31 liters/min 60 psi 1.0" TC "Ladish" 080-797PSX-5 Tubing with 1" TC Ladish 60 liters/min 60 psi SciTemp Monitors
Voltage Part Number Form Factor 110 VAC 080-790 Bench-Top Monitor 220 VAC 081-790 Bench-Top Monitor 24 VDC 080-791 DIN Rail Mount - SciTemp Sensing Element Specs
-
- All wetted materials are made of animal-free compounds.
- Material, Fluid Contact: Medical Grade Polysulfone - meets USP Class VI and FDA 21 CFR 177.1520.
- Compatible with most sanitizing agents such as NaOH, Hypochlorite. The sensors can also be repeatedly autoclaved. Gamma Radiation Stable.
- Sensor Type: Thermistor, Epoxy-Coated, 2252 Ohms
- Temperature Range: -40 to +150 °C
- Accuracy: ± 0.5 °C in the 4.00 to 70.00 °C Range
- Sensor Cable & Connectors: Lockable & Waterproof
- Sensor Microchip: EPROM, Stored Sensor ID and Cal. Factor.
- Available Connectors:
- Types: Luer, 3/8" Barb, 1/2" Barb, 3/4" TC (Tri-Clover), and 1.0" TC (Tri-Clover)
- SciTemp Monitor Specs
-
- Power Supply: Wall Transformer, 115/230 VAC.
- Monitor Display: 2 Lines, 20 Characters each, Backlit.
- Data Entry: Membrane Switch, 6 Keys.
- Standard Digital I/O: RS-232.
- Sensor Inputs: Up to Two SciTemp Temperature Sensors (T1 and T2) Hookups.
- Sensor Readout: Display of Sensors T1 and T2 as well as Differential Temperature (DT)
- Barcode Scanner Hook-up: Optional, Allows Sensor ID and Cal-Factor to be scanned into Monitor.
- Temperature Units: °C, °F.
- Temperature Range, High: 100 °C, Analog Out at 100% (default).
- Temperature Range, Low: 0 °C, Analog Out at 0% (default).
- Serial Com: BR=9600, WL=8, SB=2, PT=N.
- Alarm Outputs:
- Temperature 1 Hi/Lo
- Temperature 2 Hi/Lo
- Differential Temperature Hi/Lo
- Print Time: User-Selectable, 1 to 60 Seconds.
- Time/Date: All Data Printout with Time/Date Stamp.
- Parameter Lock-Out: Requires Password.
- Re-Calibration: Custom Temperature Calibration.
- Material Certificates
-
- BSE Material Compliance Statement SciLog Disposable Sensors Rev A AD080610.pdf
- Material Compliance Statement Concerning Use of Latex SciLog Disposable Sensors.pdf
- USP Biological Reactivity Tests In Vivo Material Compliance Statement SciLog Disposable Sensors.pdf
- USP Class VI Material Compliance Statement SciLog Disposable Sensors Rev A AD080610.pdf
- Performance Data
- Regulatory Compliance